Electric Power

  • Specs Summary
  • Rating Range
    30-5000A
  • Transfer Type
    Open / Closed / Delayed
  • Switch Type
    Molded Case and Power Breaker
  • Input control voltage

ATC Service Entrance Rated MCCB & Power Breaker Based ATS

Cat® Service Entrance Rated (SER) automatic transfer switches (ATS) are designed to provide standby power emergency power to entire installation loads to protect against utility power interruption; yet allow the ATS to be as close as possible to the point of service entrance. By safely and in code compliance, integrating the necessary overcurrent protection and service disconnecting means into the automatic transfer switch, a single installation can be made at the service entrance. This design eliminates the need for a separate upstream fault protection and respective interconnections, which in turn reduces installation space, time, and cost. Breaker-based Service Entrance Rated transfer switches are available from 30A to 5000A.

Technical Summary

  • Rating Range 30-5000A
  • Transfer Type Open / Closed / Delayed
  • Switch Type Molded Case and Power Breaker

ATC Controller Specifications

Ratings

  • MCCB 30-1000A 2, 3, or 4 Pole
  • Fixed Mount Power Breaker 200-3200A 2, 3, 4-Pole
  • Drawout Power Breaker 200-5000A 2, 3, or 4-Pole
  • System Voltage Application 120-600 Vac 50/60 Hz
  • Withstand (Power Breaker) Up to 100 kAIC at 600V 3 cycles
  • Applicable Testing
    UL 1008 listed up to 3200A

    4000A, and 5000A UL 891 listed

Standard Equipment

Controls and Wiring

  • All controls relays and industrial grade relays are totally encapsulated to minimize exposure to dust and dirt. Lugs are 90º rated and all control wire is #16 AWG, type XLPE with a 125º temperature rating.

Enclosure

  • Durable powder-coated steel NEMA 1, 3R or 12 enclosures with three door hinges to ensure proper support of the door and door mounted devices. The hinges have removable hinge pins to facilitate door removal for easy wall mounting or service and are supplied with pad-lockable latches.

Optional Equipment

Available Options

  • Open, closed or delayed transition
  • Integral overcurrent protection
  • 4-position test switch
  • Multi-meter options available
  • Selectable automatic or non-automatic operation
  • Space heaters
  • Load sequencing contacts
  • Surge suppression
  • Remote communications
  • Seismic Zone 4 Qualified (BOCA, CBC, IBC, UBC and OSHPD)
  • Field selectable, multi ratio, control voltage transformer 50/60 Hz
  • Communications for the ATC-300+ controller via RS-232 or Modbus through an integrated RS-485 port

Optional Delayed Transition includes:

  • Time delay neutral
  • Pre-transfer signal with 1 N.O. and 1 N.C. contacts